Summary



The system pulse agent fails with an error.

Error Messages



Caused by:
com.ibm.websphere.ce.cm.ObjectClosedException: DSRA9110E: Connection is closed.
at com.ibm.ws.rsadapter.jdbc.WSJdbcWrapper.createClosedException(WSJdbcWrapper.java:110)
at com.ibm.ws.rsadapter.jdbc.WSJdbcConnection.activate(WSJdbcConnection.java:2848)
at com.ibm.ws.rsadapter.jdbc.WSJdbcConnection.getAutoCommit(WSJdbcConnection.java:1968)


Steps to Reproduce



Unknown

Root Cause



A third-party product issue:
The connection from Websphere is closed.


Resolution



Make the following change to the operating environment:

Make the following changes in the Websphere Admin Console:
  1. Navigate to Data sources > PegaRULES > WebSphere Application Server data source properties.
  2. Select the following under Connection Validation Properties and save the changes:
    • Validate new connection
    • Validate existing pooled connections
  3. Navigate to Data sources > PegaRULES > Connection pools.
  4. Set the maximum number of connections to 100.

Published November 3, 2016 - Updated October 8, 2020

Was this useful?

0% found this useful

Have a question? Get answers now.

Visit the Collaboration Center to ask questions, engage in discussions, share ideas, and help others.

Did you find this content helpful?

Want to help us improve this content?

We'd prefer it if you saw us at our best.

Pega Community has detected you are using a browser which may prevent you from experiencing the site as intended. To improve your experience, please update your browser.

Close Deprecation Notice
Contact us