Summary



The content width in the grid layout is set to "Fill (100%)" and "Responsiveness" is selected. However, a horizontal scroll bar appears with 1280 x 1024 screen resolution when the screen is displayed.

Instead of the screen adjusting itself when width of the window is reduced, the content hides with the appearance of horizontal scroll bar. Selection of "Enforce CSS minimum width" checkbox in "Display Options" tab of the harness is not persisted after saving and check-in of the harness.


Error Messages



Not Applicable.

Steps to Reproduce



1. Create a grid layout with report definition as a data source.
2. Set content width to "Fill (100%)" in "Presentation" tab of the grid properties and select "Responsiveness".
3. Select "Enforce CSS minimum width" in "Display Options" tab of the harness.


Root Cause



The issue is specific to custom implemenation. The grid layout has responsiveness checked and also the priority of the column is marked as secondary.

Resolution



Copy the working repeat grid to the section that has the non-working repeat grid, then remove the non-working grid. The reponsiveness works fine and the scrollbar does not appear.

Published June 12, 2015 - Updated October 8, 2020

Was this useful?

0% found this useful

Have a question? Get answers now.

Visit the Collaboration Center to ask questions, engage in discussions, share ideas, and help others.

Did you find this content helpful?

Want to help us improve this content?

We'd prefer it if you saw us at our best.

Pega Community has detected you are using a browser which may prevent you from experiencing the site as intended. To improve your experience, please update your browser.

Close Deprecation Notice
Contact us