Support Article
InitializationFailedError in log file during PRPC start-up
SA-6265
Summary
PRPC server does not start-up after developers have recently deployed a Product file containing Rules and Instances.
ERROR MESSAGES
com.pega.pegarules.pub.context.InitializationFailedError: PRNodeImpl init failed
com.pega.pegarules.pub.context.PRSecurityException: Unable to construct authorization core due to authorization failure
com.pega.pegarules.pub.context.InvalidConfigurationException: No such Rule-Application instance: DEMO 01.01.22
STEPS TO REPRODUCE
Deploy the product file and restart PRPC
ROOT CAUSE
The application referenced by the Access Group inside the RequestorType was having invalid entry.
RESOLUTION
Suggested developer to change the System Name in the prconfig.xml to "pega" and restart the server. This should help overcome the PRPC start-up error.
<env name="Identification/SystemName" value="pega" />