Summary



Not able to open the remote tracer from the System Management Application (SMA). When tracer is started from within SMA, an error is thrown.


Error Messages



404 error


Steps to Reproduce



Make an attempt to remote trace in SMA.


Root Cause



A defect or configuration issue in the operating environment
The URL of the monitored node is not specified correctly in SMA.

Resolution



Make the following change to the operating environment:

In SMA modify the node configuration details in order to update the PRPC Primary URL.

Update URL to include the context,

From

https://your_host:your_port/PRServlet

To

https://your_host:your_port/prweb/PRServlet