Tracer not working with encrypting URLs

SA-18011

Summary



When enabling the following prconfig settings, user tried to open tracer and observed an error, “Connection ID is empty. Please restart Tracer”

<env value="required" name="Initialization/SubmitObfuscatedURL"/>
<env value="true" name="Initialization/Urlencryption"/>



Error Messages



“Connection ID is empty. Please restart Tracer”

Steps to Reproduce



1. Stop application server.
2. Update prconfig.xml with:
       <env value="required" name="Initialization/SubmitObfuscatedURL"/>
        <env value="true" name="Initialization/Urlencryption"/>
3. Restart the server and log into the Designer Studio.
4. Start the tracer.


Root Cause



A defect in Pegasystems’ code or rules.
In TracerTraceGeneralScript HTML fragment rule, using the encrypted URL to open the tracer, is causing the issue.


Resolution



Apply HFix-25343.