Support Article
Unable to create performace test scripts using LoadRunner
SA-17465
Summary
Unable to create performance test scripts using Load Runner after Pega 7 upgrade.
Scripts were working fine with PRPC 5.4.
Dynamically changing URLs are generated from client side. However, the load runner can capture dynamically changing values only if it is received from the server response.
Error Messages
Not Applicable
Steps to Reproduce
1. Open Virtual Generator (in Load Runner)
2. Record the work flow
3. Attempt to replay
Root Cause
A configuration issue in the operating environment prevents recorded scenarios from replaying correctly - URL encryption is enabled. Each request is encrypted specific to that session or requestor and cannot be replayed outside the context of that session or requestor.
Resolution
Disable URL encryption to allow automated performance testing tools to work correctly.
Published January 31, 2016 - Updated October 8, 2020