After deployment, the higher version rules are not used

SA-8606

Summary



When using prpcUtils to import section rules, the section rules are not displayed by the application until revalidate-and-save is used on them. This is in contrast to using the import landing page, which does not show the same issue.

Error Messages



Not Applicable

Steps to Reproduce



Use the "prpcUtils import" command-line feature to import a zip file produced from a Rule-Admin-Product rule.

Root Cause



The version of the prpcUtils being used for performing the import was 7.1.6 but the import was being performed to a 7.1.7 system.  As a result, the assembly version as shown on the console output mismatched. In particular, the 7.1.6 prpcUtils displayed assembly version: 1292740085. The assembly version for 7.1.7 is 1239066975.

Due to this mismatch, the system by design did not invalidate the cache.

Resolution



By using the 7.1.7 version of prpcUtils, the cache invalidates properly and the section rule displays without any revalidate-and-save needed.
 

Published June 12, 2015 - Updated October 8, 2020

Was this useful?

0% found this useful

Have a question? Get answers now.

Visit the Collaboration Center to ask questions, engage in discussions, share ideas, and help others.

Did you find this content helpful?

Want to help us improve this content?

We'd prefer it if you saw us at our best.

Pega Community has detected you are using a browser which may prevent you from experiencing the site as intended. To improve your experience, please update your browser.

Close Deprecation Notice
Contact us