Data Transform cannot take parameter when calling from connector

SA-14422

Summary



Data Transforms called on a Connector rule of a flow (on Integration layer), do not allow parameters to be passed, though input parameters are defined in the data transform.


Error Messages



Not Applicable


Steps to Reproduce



1. Create a Flow in Integration layer.
2. Crate a data transform with parameters in Integration layer.
3. On one of the connectors of this flow, try to call the data transform mentioned above.



Root Cause



A defect in Pegasystems’ code or rules. When a flow is in Data- or Int- classes (other than work classes), if workclass is set to any work class on the design tab, then the data transform doe not populate its parameters.
The issue is that, when the class name is not passed to the section, pzRuleCallParams, then it takes from work class. But it should take from pyClassName.



Resolution



Install HFix-23800.