Tracer Disabled error when tracing a web service

SA-6386

Summary



During the tracing of a web service, the Tracer log shows the error Tracer Disabled.

Error Messages



Tracer disabled.


Root Cause



During Tracer operation, by default, the system saves unprocessed events in a temporary file that is limited to 500 items. 
In some tracing situations, this can cause the display to lag behind the processing being traced or cause the Tracer display to be incomplete or fail. If the buffer exceeds the limit of 500 items, Tracer processing ends. 


Resolution



To avoid this condition, you can specify that the system save more events in the temporary file. To prevent runaway or looping operations, the disk file mechanism also has a maximum size; the default is 50,000 unprocessed events.

Edit the prconfig.xml file to adjust the size of the Tracer file buffer, as explained in the Help topic:

https://pdn.pega.com/sites/pdn.pega.com/files/help_v62/procomhelpmain.htm#tools/tracer/tracerxml.htm


 

Published June 9, 2016 - Updated October 8, 2020

Was this useful?

100% found this useful

Have a question? Get answers now.

Visit the Collaboration Center to ask questions, engage in discussions, share ideas, and help others.

Did you find this content helpful?

Want to help us improve this content?

We'd prefer it if you saw us at our best.

Pega Community has detected you are using a browser which may prevent you from experiencing the site as intended. To improve your experience, please update your browser.

Close Deprecation Notice
Contact us