Support Article
Missing functions observed post Pega 7.1.8 installation
SA-13679
Summary
PR_READ_FROM_STREAM and other functions are missing after installing Pega 7.1.8.
Error Messages
Not Applicable
Steps to Reproduce
- Run generateudf script and have a DBA apply the schema changed.
- Run the IUA (Installation and Upgrade Assistant) and choose to Bypass Automatic DDL Application
Root Cause
The root cause of this issue stems from the fact that the Bypass Automatic DDL Application checkbox has been updated to no longer install the UDFs as of Pega 7.1.8. However, the documentation regarding this was not updated.Resolution
Our recommendation to apply the UDFs is to update the setupDatabase.properties file with database connection information (including schema names) and then run the generateudf script.
Published September 7, 2015 - Updated October 8, 2020
Have a question? Get answers now.
Visit the Collaboration Center to ask questions, engage in discussions, share ideas, and help others.